Medium - Inspection Needed

Electrolux Dishwasher i70 Error Code

i70 means the NTC temperature sensor value is out of range, between 0.04 and 4.7 volts being valid. Electrolux’s list explains that the thermistor sits within the turbidity sensor, and the fix is to replace the turbidity sensor. The program…

What i70 Means

i70 means the NTC temperature sensor value is out of range, between 0.04 and 4.7 volts being valid. Electrolux’s list explains that the thermistor sits within the turbidity sensor, and the fix is to replace the turbidity sensor. The program continues without the heater.

Common Causes of i70

  • Thermistor inside the turbidity sensor failed
  • Sensor harness loose

🔧 One Safe Check You Can Try

Nothing to adjust as an owner. Dishes may come out cooler until it is repaired.

⚠ Why You Shouldn't Go Further Than That

  • The turbidity sensor is mounted in the sump under the tub.
  • Without temperature sensing the heater cannot be used.

Opening a panel to inspect or repair something yourself doesn't automatically cancel your manufacturer's warranty — but it can risk accidental damage, and some manufacturers do have specific service conditions. Check your product's warranty terms, or ask us, before deciding.

Other Dishwashers Error Codes

Related Guides

Still Seeing i70?

Book a trained technician and get it diagnosed correctly the first time — no guesswork, no repeat visits.

Book Repair for i70

Same-day & next-day appointments · No hidden fees · Technicians trained on these appliances

1Service Details
2Date & Time
3Contact Info

or call (844) 483-2989 now

FAQ

i70 FAQ

A sensor in the sump that measures how cloudy the water is. On these models it also carries the temperature thermistor.

Yes, but without heating.