The EIGD55I monitors air entering the drum with an inlet thermistor as well as the outlet one. E73 means that sensor reads open and E74 means shorted; the expected range is tens of kilohms at room temperature, so the reading tells us quickly whether it is the sensor.
Lint that escapes a worn filter collects around the burner on an EIGD55I. We vacuum the burner area on every gas service call; it is a fire risk as well as a heating problem.
Key Features
- Gas front-load dryer, IQ-Touch controls
- Builds EIGD55IKG and EIGD55IRR, with revisions 0 to 2
- Covered by the front-load gas and electric dryer installation and use guides
Most Common Issues on This Model
Burner lights and drops out
E73 or E74 inlet thermistor codes
Lint buildup around the burner tube