The EFMG617STT has its own Electrolux service manual shared with the electric 617, which gives us test points and resistance values for the thermistors and sensors. That means a no-heat call can be narrowed down with a meter instead of swapping parts.
Dryer sheets and fabric softener leave a film on the moisture sensor bars of an EFMG617STT, and the dryer then ends sensor cycles while clothes are still damp. Wiping the bars with rubbing alcohol often fixes it without a part.