Electrolux Dryers

Electrolux EIED50LIW

Model # EIED50LIW

The EIED50LIW has no steam, so its water-free design keeps repairs to heat, airflow and the motor. E52 means the motor stopped or would not start; an overloaded drum or an overheated motor whose protector is resetting can cause it, and the protector may take half an hour to cool.

When an EIED50LIW logs E65, the high limit has tripped too many times. The limit is doing its job, so we clear the vent before replacing anything.

Key Features

  • Electric front-load dryer, white (LIW)
  • Revision builds EIED50LIW0, LIW1 and LIW2
  • Specifications: electric front load dryer

Most Common Issues on This Model

01

E65 high limit trip count from poor venting

02

E52 motor not starting under heavy loads

03

Thermal limiter open with no heat

Error Codes Common to This Model

Own This Model? Book a Diagnosis.

Have the model number to hand when you book, so the technician arrives knowing which parts this model uses and where it usually fails.

Book Your Repair Today

Same-day & next-day appointments · No hidden fees · Technicians trained on these appliances

1Service Details
2Date & Time
3Contact Info

or call (844) 483-2989 now

FAQ

Electrolux EIED50LIW FAQ

Remove part of the load and let the dryer rest for about 30 minutes; the motor protector needs time to reset. If E52 returns with a normal load, the motor and its relay are tested.