Model # EIGD50LIW

The EIGD50LIW is one of the gas dryers from the L-generation IQ-Touch line. On gas models the inlet and outlet thermal limiters both show up under E66, so we check both when the dryer stops heating.

An EIGD50LIW that heats for the first few minutes and then runs cold is the classic sign of tired gas valve coils; they work cold and fail once they warm up.

Key Features

  • 27-inch gas front-load dryer (specifications)
  • White finish, revision EIGD50LIW0
  • IQ-Touch L generation

Most Common Issues on This Model

01

Gas valve coils weakening with age

02

E66 thermal limiter open

03

Rollers and idler pulley noise

Error Codes Common to This Model

Own This Model? Book a Diagnosis.

Have the model number to hand when you book, so the technician arrives knowing which parts this model uses and where it usually fails.

Book Your Repair Today

Same-day & next-day appointments · No hidden fees · Technicians trained on these appliances

1Service Details
2Date & Time
3Contact Info

or call (844) 483-2989 now

FAQ

Electrolux EIGD50LIW FAQ

Typically the gas valve coils, which work cold and drop out once warm. A technician tests them hot and cold.

A thermal limiter is open. Electrolux lists the outlet limiter, and on gas models the inlet limiter too.