The E32AF85PQS all-freezer shows a sensor problem as E8 or E9 alternating with -10 F, and then keeps running at its factory setting. Its Power Fail light tells you the cabinet passed 23 F during an outage and, if it lasted over an hour, for how long.
The Custom Set control on the E32AF85PQS can be switched OFF by pressing UP three extra times at 10 F, which is the first thing we rule out on a warm column.
Key Features
- Icon 32-inch built-in all-freezer
- Custom Set control, -10 F to 10 F
- Pure Advantage air filter (EAFCBF)
Most Common Issues on This Model
E8/E9 sensor alarm with -10 F on the display
Power Fail indicator after outages
Accidental OFF